Audi Leak Light Tightness Tester

The station is prepared for installation into a conveyor system. The floodlight located on the floodlight pallet/carrier enters the tightness station on the conveyor system. Then, the barcode is scanned to identify the light: L/P, HALOGEN, LED, XEN etc. When the type of the floodlight is detected, the bottom appliance with the technology of filling, measuring and clogging is automatically readjusted by the stepping motor. The same procedure takes place for the top and front appliance. The automat lifts the carrier, including the floodlight, from the conveyor belt and tightens the floodlight and starts the measurement defined for the given type.

The testing position executes the following

  • Inspection of the completion of vulcanization
  • Inspection of the presence of connecting clamps
  • Inspection of the tightness of the floodlight according to the customer’s requirements
  • Inspection of the barcode of the floodlight
  • Inspection of the Matrix code
  • Inspection of the presence and correct position of stuffing
  • Inspection of the presence of the GORE-TEX membrane

 

The total cycle length is 43s for one floodlight.

Audi Leak Light Tightness Tester

Audi Leak Light Tightness Tester